Quick Details

  • Standard or Nonstandard: Standard
  • Structure: Control
  • Pressure: Low Pressure
  • Power: Solenoid
  • Material: Stainless Steel
  • Temperature of Media: Low Temperature
  • Media: Refrigerants
  • Port Size: 1.9
  • Place of Origin: Sichuan, China (Mainland)
  • Model Number: FDF-2A
  • Brand Name: TF or OEM
  • Allowable refrigerants: R134a,R407C, R404A, R410A, R22
  • Operation: Normally Closed
  • Allowable temperature of refrigerant: -25~+120
  • Maxim working pressure: 3.0MPa

Packaging & Delivery

Packaging Details Standard export packing or according to customers' requirement
Delivery Time 25-30 days after receipt of P.O.

 

Small Solenoid Valves 

 

- Saving cost for additional operations, we have diefferent pipe configurations.

 

 

  

 

  

-Wide production line-up for various applications, normally open type / normally closed type 

direct type / pilot type

 

Applications;

 

- Air conditioner

- Dehumidifiers

- Vending machines

- Ice-making machines

- Water Dispensers etc...

 

Specifications:

 

ModelsFDF-2AFDF-4AFDF-6A
Max. Working Pressure3.3 Mpa3.3 Mpa3.3 Mpa
Water Test Pressure (with water pressure) 4.5 Mpa4.5 Mpa4.5 Mpa
Air tight Test Pressure (with air pressure)3.3 Mpa3.3 Mpa3.3 Mpa
Allowable Ambient Temperature C          -30   ~  +50 C
Fluid Temperature C          -30  ~ +120 C
Ambient Humidity  RH          max. %95 RH
Connection mm               6.35          6.35          8.00
Port Size               1.90          4.00          5.80

 

 

Testing Methods:

 

The ex-factory inspection and all-function test, technical requirement and test method of Solenoid valve should be in compliance with table 1. Among which the ex-factory inspection should be taken as the following: take the whole quantity of valves produced in one shift as a inspection lot, pick-sample and inspect as per normal-level one-time sampling program noted in the sampling table and each lot sample-account program stipulated in GB/T2828-1987, inspection level II. All-function test should be taken as per GB/T2829-1987, judgment level I, twice sampling.

 

 Table1

NoItemEx-factory inspectionAll Function TestAQLRQL
1Appearance0.6550
2Hydraulic pressure  50
3Air-tightness0.2530
4Operative pressure difference0.2530
5Internal leakage0.2530
6Temperature rise of solenoid coil   
7Flow rate  30
8Insulation resistance0.15 
9Electric strength   
10Insulation between coil circles0.2530
11Constant wet-hot test  30
12Salt-spray test  30
13Life test  30
14Vibration resistance  30
15Noise0.2530
16Burst pressure  50
17High temperature resistant test  30
18Low temperature resistant test  30
19High and low temperature resistance test  30

 

  Table2

RQLSample QuantityAcceptable number AcReject number Re
30First time 402
Second time 401
50First time 202
Second time 201

 

 

For more information and products references please contact with us. 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer, Trading Company
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $59,000
Learn More